DFH For Organic Solutions Acids and Alkali
Xunling
DFH
Availability: | |
---|---|
Air can be drawn directly from the laboratory room into the fume hood, creating negative pressure, and the airflow at a stable face velocity creates a natural barrier to isolate users from the chemicals they handle.
The fan system sucks toxic and harmful fumes upward, then the airflow takes contaminations into the filtration system. The filters can be customized based on the chemicals needs to purify.
The contaminations will be absorbed on the filter’s internal space, recirculating clean air back to room.
No need to install ductwork, no conditioned air exhausted out, energy saving and cost effective.
Assembled shipping and ready to use. Can be a benchtop type or free standing to be placed at wherever in the lab room.
The filtration system can be customized to meet different application requirements.
Always safe, face velocity can be adjusted to be stable from 0.3 m/s to 0.7 m/s.
Width (mm) | 800 mm | 1000 mm | 1275 mm | 1600 mm | 1600 mm (Deeper) |
Overall Size of free standing W*D*H (mm) | 800*620*2070 | 1000*620*2070 | 1275*620*2070 | 1600*620*2070 | 1600*790*2070 |
Overall Size of Benchtop Type W*D*H (mm) | 800*620*1245 | 1000*620*1245 | 1275*620*1245 | 1600*620*1245 | 1600*790*1245 |
Internal Size W*D*H (mm) | 781*574*934 | 981*574*934 | 1256*574*934 | 1581*574*934 | 1581*744*934 |
Airflow Face Velocity ( m / s) | 0.3 ~0.7 | 0.3 ~0.7 | 0.3 ~0.7 | 0.3 ~0.7 | 0.3 ~0.7 |
Filtration System | Prefilters+Organic Filters+Acids & Alkali Filters | ||||
Monitoring & Alarming Sys | Temperature, Humidity, Filter Loading | ||||
Optional Accessories | Air Velometer, Water Sink, Water Tap, Gas Cock |
If you are wondering whether this ductless fume hood can filter your chemical substances or not ?
Please go to our download center or simply check this: https://iqrorwxhnkqplk5p.ldycdn.com/Xunling+Ductless+Fume+Hood+Adsorption+Capacity+for+Common+Chemical+Reagents-aidloBplKnillSRnjnrqmkqiq.pdf
More chemicals are waiting to be tested into this list.
How well is this ductless fume hood filtration effectiveness ?
What they don't tell you before choosing a ductless fume hood ?
Check this: https://www.labcleantech.com/how-to-make-a-better-filtration-system.html
Air can be drawn directly from the laboratory room into the fume hood, creating negative pressure, and the airflow at a stable face velocity creates a natural barrier to isolate users from the chemicals they handle.
The fan system sucks toxic and harmful fumes upward, then the airflow takes contaminations into the filtration system. The filters can be customized based on the chemicals needs to purify.
The contaminations will be absorbed on the filter’s internal space, recirculating clean air back to room.
No need to install ductwork, no conditioned air exhausted out, energy saving and cost effective.
Assembled shipping and ready to use. Can be a benchtop type or free standing to be placed at wherever in the lab room.
The filtration system can be customized to meet different application requirements.
Always safe, face velocity can be adjusted to be stable from 0.3 m/s to 0.7 m/s.
Width (mm) | 800 mm | 1000 mm | 1275 mm | 1600 mm | 1600 mm (Deeper) |
Overall Size of free standing W*D*H (mm) | 800*620*2070 | 1000*620*2070 | 1275*620*2070 | 1600*620*2070 | 1600*790*2070 |
Overall Size of Benchtop Type W*D*H (mm) | 800*620*1245 | 1000*620*1245 | 1275*620*1245 | 1600*620*1245 | 1600*790*1245 |
Internal Size W*D*H (mm) | 781*574*934 | 981*574*934 | 1256*574*934 | 1581*574*934 | 1581*744*934 |
Airflow Face Velocity ( m / s) | 0.3 ~0.7 | 0.3 ~0.7 | 0.3 ~0.7 | 0.3 ~0.7 | 0.3 ~0.7 |
Filtration System | Prefilters+Organic Filters+Acids & Alkali Filters | ||||
Monitoring & Alarming Sys | Temperature, Humidity, Filter Loading | ||||
Optional Accessories | Air Velometer, Water Sink, Water Tap, Gas Cock |
If you are wondering whether this ductless fume hood can filter your chemical substances or not ?
Please go to our download center or simply check this: https://rororwxhnkqplk5p.ldycdn.com/Xunling+Ductless+Fume+Hood+Adsorption+Capacity+for+Common+Chemical+Reagents-aidloBplKnillSRnjnrqmkqiq.pdf
More chemicals are waiting to be tested into this list.
How well is this ductless fume hood filtration effectiveness ?
What they don't tell you before choosing a ductless fume hood ?
Check this: https://www.labcleantech.com/how-to-make-a-better-filtration-system.html