Availability: | |
---|---|
1: Provides sterile work zone that meets and exceeds ISO Class 5 and FS209E100
2: Pre-installed germicidal UV lamp for sterilization
3: Equipped with Pre-filters, and HEPA/ULPA filters to prevent airborne contaminants
4: Polycarbonate and polypropylene construction to reflect UV irradiating evenly
5: UV shelf with built-in pipettor holder
6: Lab event timer
7: Digital UV light time setting: 01-59 minutes
8: Complete assembled shipping, no need for ductwork
9: Support flexible airflow control
10: LED lighting
11: Available for desktop use or installation on an optional base stand or mobile cart
1: Real-time monitor temperature, humidity, filters loading, and UV lamp status
2: visually and audibly alarming if Low airflow or working abnormal
3: Overlapping polycarbonate sash to avoid UV light exposure
4: Window and UV lamp is interlocked. If sash is raised, automatically turns off UV light and activates fan
5: Filters and electronics are placed above the workspace, preventing chemical spill pollution
Airflow in the PCR Cabinet
ⅰ. Room air is filtered by electrostatic Pre-filter and pumped from A, particulates equal to or larger than 0.5 microns will be removed there.
ⅱ. The Airflow continuously passes through the HEPA filter at B, particulates equal to or larger than 0.3 microns can be removed here.
ⅲ. Cleaned Vertical Laminar Airflow blows down from C, then goes back from D to the cabinet inside, keeping a sterile environment of ISO Class 5 and FS209E 100 standards.
ⅳ. The UV Lamp light will sterilize the living organisms on the pipetting gun, test tube, beaker, and other experimental instruments, avoiding any possible cross-contamination.
Model | PCR120S (Standard Height) | PCR120ST (Tall Version) |
External Size W*D*H | 1220*650*740 mm | 1220*650*990 mm |
Internal Size W*D*H | 1190*640*450 mm | 1190*640*700 mm |
Max Purified Air Volume | 11.2m³/min | |
Lighting | LED, 16W, 600lux | |
UV Light | 254 nm, 30W | |
Instrument rack L*W*H | 1220*650*864 mm | |
Sides and back Panel | Polycarbonate | |
Blower / Fan | EC Axial Flow Fan | |
Filter Efficiency | >99.997℅ at aerosol and particulates of 0.3 μm (microns)diameter or above | |
Cleanliness level | ISO Class 5 and FS209E 100 | |
Abnormal Alarm | visually and audibly | |
Airflow Rate & Blower speed | Adjustable |
1: Provides sterile work zone that meets and exceeds ISO Class 5 and FS209E100
2: Pre-installed germicidal UV lamp for sterilization
3: Equipped with Pre-filters, and HEPA/ULPA filters to prevent airborne contaminants
4: Polycarbonate and polypropylene construction to reflect UV irradiating evenly
5: UV shelf with built-in pipettor holder
6: Lab event timer
7: Digital UV light time setting: 01-59 minutes
8: Complete assembled shipping, no need for ductwork
9: Support flexible airflow control
10: LED lighting
11: Available for desktop use or installation on an optional base stand or mobile cart
1: Real-time monitor temperature, humidity, filters loading, and UV lamp status
2: visually and audibly alarming if Low airflow or working abnormal
3: Overlapping polycarbonate sash to avoid UV light exposure
4: Window and UV lamp is interlocked. If sash is raised, automatically turns off UV light and activates fan
5: Filters and electronics are placed above the workspace, preventing chemical spill pollution
Airflow in the PCR Cabinet
ⅰ. Room air is filtered by electrostatic Pre-filter and pumped from A, particulates equal to or larger than 0.5 microns will be removed there.
ⅱ. The Airflow continuously passes through the HEPA filter at B, particulates equal to or larger than 0.3 microns can be removed here.
ⅲ. Cleaned Vertical Laminar Airflow blows down from C, then goes back from D to the cabinet inside, keeping a sterile environment of ISO Class 5 and FS209E 100 standards.
ⅳ. The UV Lamp light will sterilize the living organisms on the pipetting gun, test tube, beaker, and other experimental instruments, avoiding any possible cross-contamination.
Model | PCR120S (Standard Height) | PCR120ST (Tall Version) |
External Size W*D*H | 1220*650*740 mm | 1220*650*990 mm |
Internal Size W*D*H | 1190*640*450 mm | 1190*640*700 mm |
Max Purified Air Volume | 11.2m³/min | |
Lighting | LED, 16W, 600lux | |
UV Light | 254 nm, 30W | |
Instrument rack L*W*H | 1220*650*864 mm | |
Sides and back Panel | Polycarbonate | |
Blower / Fan | EC Axial Flow Fan | |
Filter Efficiency | >99.997℅ at aerosol and particulates of 0.3 μm (microns)diameter or above | |
Cleanliness level | ISO Class 5 and FS209E 100 | |
Abnormal Alarm | visually and audibly | |
Airflow Rate & Blower speed | Adjustable |