SH-2: | |
---|---|
SH-3: | |
Availability: | |
Lab Magnetic Mixer Stirrer with Hot Plate
Base with power switch, two knobs and attached hot plate 1”Teflon coated magnetic stir bar.
Power cord.
Support stand (base rod, extender rod, right angle clamp and thermometer holder).
To set up the support stand:
Screw the two rods together making one support rod.
Make sure they fit tightly.
Insert the slotted end of the rod into the plastic holder on the back of the base.
Slip the right angle clamp onto the support rod and tighten the knob.
Slide in the thermometer holder and tighten the other knob.
The height of the thermometer holder can be adjusted by moving the clamp up or down on the support.
To use the hot plate:
1. Make sure the knobs are turned off. The white mark on each knob should be pointed down.
2. Connect the power cord to the back of the base. The base should be set on a
hard surface, like a countertop or table.
3.Plug the other end of the power cord into a standard outlet.
4. Filp the power switch on the right side of the base. The line(-) indicates on
and the circle (o) indicates off.
WARNING: Be very careful with the hotplate after turned on. Do NOT touch the aluminium surface as it gets very hot and can cause severe burns.
5.Rotate the right knob in a clockwise direction. At maximum power, the hot plate will take around 20-30 minutes to boil a large beaker of water. The surface in the middle of the plate can reach 350°C( 662℉)when the knob is turned all the way to maximum power.
6. Adjust the knob to keep the desired heat level, using a thermometer to check the temperature of the solution.
7. To turn off the hot plate, rotate the knob counter-clockwise until you hear a click and the white mark is pointing own.
8. Make sure both knobs are off and the flip power is switched off. Unplug the cord from the power outlet.
To use the magnetic stirrer
Drop the stir bar into the solution.
Turn on the magnetic stirrer by flipping the power switch on (-), then rotating the left knob in a clockwise direction.
The further you rotate the knob, the faster it will spin to stir the solution.
To turn off the magnetic stirrer, rotate the knob counter-clockwise until you hear a click and the white mark is pointing down. Flip the power switch off. Unplug the device.
Remove the stir bar with a metal utensil. The stir bar will stick to it so you can lift it out easily.
Model | SH-2 | SH-3 | SH-4 |
Image | |||
Heating power | 180W | 500W | 600W |
Max Mixing | 1L | 3L | 5L |
Platform Size | 120*120mm | 170*170mm | 190*190mm |
Work plate | Aluminum | Aluminum | Ceramic anti-corrosion coating |
Price ( Exw Factory USD) | 45 | 80 | 100 |
Maximum heating plate temperature | 380°C | ||
Speeed Range | 0-1600 RPM | ||
Voltage | 110V/220V , 50/60HZ | ||
Control mode | Double spin buttons | ||
Heating | Yes |
Lab Magnetic Mixer Stirrer with Hot Plate
Base with power switch, two knobs and attached hot plate 1”Teflon coated magnetic stir bar.
Power cord.
Support stand (base rod, extender rod, right angle clamp and thermometer holder).
To set up the support stand:
Screw the two rods together making one support rod.
Make sure they fit tightly.
Insert the slotted end of the rod into the plastic holder on the back of the base.
Slip the right angle clamp onto the support rod and tighten the knob.
Slide in the thermometer holder and tighten the other knob.
The height of the thermometer holder can be adjusted by moving the clamp up or down on the support.
To use the hot plate:
1. Make sure the knobs are turned off. The white mark on each knob should be pointed down.
2. Connect the power cord to the back of the base. The base should be set on a
hard surface, like a countertop or table.
3.Plug the other end of the power cord into a standard outlet.
4. Filp the power switch on the right side of the base. The line(-) indicates on
and the circle (o) indicates off.
WARNING: Be very careful with the hotplate after turned on. Do NOT touch the aluminium surface as it gets very hot and can cause severe burns.
5.Rotate the right knob in a clockwise direction. At maximum power, the hot plate will take around 20-30 minutes to boil a large beaker of water. The surface in the middle of the plate can reach 350°C( 662℉)when the knob is turned all the way to maximum power.
6. Adjust the knob to keep the desired heat level, using a thermometer to check the temperature of the solution.
7. To turn off the hot plate, rotate the knob counter-clockwise until you hear a click and the white mark is pointing own.
8. Make sure both knobs are off and the flip power is switched off. Unplug the cord from the power outlet.
To use the magnetic stirrer
Drop the stir bar into the solution.
Turn on the magnetic stirrer by flipping the power switch on (-), then rotating the left knob in a clockwise direction.
The further you rotate the knob, the faster it will spin to stir the solution.
To turn off the magnetic stirrer, rotate the knob counter-clockwise until you hear a click and the white mark is pointing down. Flip the power switch off. Unplug the device.
Remove the stir bar with a metal utensil. The stir bar will stick to it so you can lift it out easily.
Model | SH-2 | SH-3 | SH-4 |
Image | |||
Heating power | 180W | 500W | 600W |
Max Mixing | 1L | 3L | 5L |
Platform Size | 120*120mm | 170*170mm | 190*190mm |
Work plate | Aluminum | Aluminum | Ceramic anti-corrosion coating |
Price ( Exw Factory USD) | 45 | 80 | 100 |
Maximum heating plate temperature | 380°C | ||
Speeed Range | 0-1600 RPM | ||
Voltage | 110V/220V , 50/60HZ | ||
Control mode | Double spin buttons | ||
Heating | Yes |