Laboratory wastewater treatment equipment

The comprehensive wastewater treatment system of Zhonghuan Qingyuan Laboratory consists of wastewater collection, automatic acid-base regulation device, automatic dosing device, coagulation flotation device, heavy metal removal device, new micro electrolysis device, electrochemical catalytic oxidation treatment device, ozone catalytic oxidation treatment device, photo catalytic oxidation treatment device, new biological treatment device, adsorption filtration device, new membrane filtration device and composite disinfection treatment device, To form a complete integrated wastewater treatment system. The system adopts different treatment technologies and processes for comprehensive treatment of different organic, inorganic and biological wastewater components and concentrations, which can effectively remove COD, BOD, SS, chroma, viruses, organic solvents and heavy metal ions from the comprehensive wastewater, and discharge them up to standard after treatment.

This comprehensive wastewater treatment system is an advanced, clean and efficient combination of wastewater treatment technologies, which can be widely used in domestic and foreign research institutes, colleges and universities, environmental monitoring, product inspection, food and drug inspection, entry-exit inspection and quarantine, disease control center, geological and mineral testing center, analysis and testing center, water resource monitoring, grain and oil quality inspection, petrochemical industry, animal husbandry, agricultural product testing, medical institutions, central blood stations Wastewater treatment in enterprises and other industries.

Main technical parameters of laboratory wastewater treatment equipment

♦ Overall dimensions of equipment:

♦  (The size will vary according to the processing capacity and process of the equipment)

♦ Operating power: 3KW

♦ Equipment power supply: 220V 50Hz

♦ Operating pressure: 0.1~0.6MPa

Commissioning and installation of laboratory wastewater treatment equipment

♦ The installation site must be equipped with power supply, tap water, waste water supply and drainage pipes and external vents;

♦ When installing the equipment, pay attention to adjusting the castor screws to keep the equipment horizontal;

♦ Proper tools and instruments shall be used for effective and accurate installation of equipment, and the accuracy of installation position shall be ensured;

♦ The equipment is of split design and requires on-site commissioning and installation by professional technicians;

♦ The equipment shall be debugged timely after installation.

Wastewater treatment process of laboratory wastewater treatment equipment

The treatment process will change according to the actual water quality, and the specific process shall be subject to the actual equipment process!

Operating Instructions for Laboratory Wastewater Treatment Equipment

1. Turn on the power and turn on the power switch. The system starts up and displays the welcome interface. Click the standby interface to enter the system.

Parameter setting description:

1. The range of acid and alkali is set according to the situation. The factory default is: the acid value is set to 6, and the alkali value is set to 9. The equipment will automatically add liquid medicine according to the set value to keep the PH value of wastewater between 6-9;

2. The settling time of flocs in water can be set for settling time;

3 The dosing duration of PAC/ZM pump is used to set the dosing amount;

4 Intermittent dosing time is used for the interval between two dosing;

5 Start up backwashing is a cleaning of ultrafiltration membrane before equipment operation to ensure the normal operation of ultrafiltration membrane;

6 The reaction stirring time is the time of ozone disinfection and oxidation reduction;

6. After setting, click the system overview function key to enter the screen, and click the operation icon to start the automatic operation of the device.

7. If manual operation is required, click Manual Control, and click to activate manual mode. After the manual mode lights up, it can be operated manually. When the system has faults or needs debugging, manual operation can be used under the guidance of professionals. (Do not use manual operation during normal operation. When dredging is required, please open the ball valve at the bottom of the corresponding water tank and switch to the manual state. Click the manual button of the sludge pump, and the system will start dredging.).


NEWS

  • In industrial environments where hazardous materials are handled, promoting awareness of emergency shower and eye washer stations is crucial for ensuring the safety and well-being of workers. These vital safety fixtures serve as the first line of defense in the event of chemical exposure or other em
  • In the realm of industrial ventilation and air movement, PP (Polypropylene) Tubeaxial Fans stand out as indispensable tools for ensuring optimal airflow and maintaining safe working conditions. These fans are essential components in various industries due to their efficiency, reliability, and versat
  • In industrial settings where fumes, gases, and airborne particles are produced, maintaining a clean and safe working environment is paramount. Flexible exhaust arm hoods play a crucial role in achieving this goal by efficiently extracting contaminants and improving airflow within the workspace. This
  • In an era where environmental sustainability is paramount, wastewater treatment solutions have become indispensable for ensuring the health of our planet. With advancing technologies and growing awareness of the importance of water conservation, cutting-edge wastewater treatment solutions have emerg
  • In laboratories and cleanroom environments, maintaining a high level of purity is essential for ensuring the integrity of experiments and the reliability of results. Horizontal laminar flow hoods represent a critical component in achieving this goal, as they play a significant role in creating contr
CONTACT
  +86 18688931479
  xalabfurniture@163.com
  No.5 JianGong Road, XinCheng District, Xi'an City, Shaanxi, China
CONTACT US

Contact us

© 2021 Xi'an Xunling Electronic Technology Co., Ltd . All rights reserved.丨 PrivacySitemap